repair workshop | assembly production line | institution | crane | gates
Ordering Manufacturing P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Cable type | Ø cable (mm) |
9006 | 1 X | 6 | 6 | H05V-F | 5.5 | |||
9001 | 2 X | 1 | 7 | 1.1 @230V | 1.6 @230V | 1.1 | H05VV-F | 6.5 |
9002 | 2 X | 1.5 | 5 | 1.4 @230V | 1.9 @230V | 1.4 | H05VV-F | 8 |
9003 | 3 G | 1 | 6 | 1.1 @230V | 1.6 @230V | 1.1 | H05VV-F | 65 |
9004 | 3 G | 1.5 | 5 | 1.4 @230V | 1.9 @230V | 1.4 | H05VV-F | 75 |
Ordering Manufacturing P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Cable type | Ø cable (mm) |
9006 | 1 X | 6 | 6 | H05V-F | 5.5 | |||
9001 | 2 X | 1 | 7 | 1.1 @230V | 1.6 @230V | 1.1 | H05VV-F | 6.5 |
9002 | 2 X | 1.5 | 5 | 1.4 @230V | 1.9 @230V | 1.4 | H05VV-F | 8 |
9003 | 3 G | 1 | 6 | 1.1 @230V | 1.6 @230V | 1.1 | H05VV-F | 65 |
9004 | 3 G | 1.5 | 5 | 1.4 @230V | 1.9 @230V | 1.4 | H05VV-F | 75 |
ART. 5100
Conversion kit from XF in XL
ART. 949/5000
Optional device to make the fastening bracket of XF and XL series cable reels fixed instead of pivoting.
Ordering Manufacting P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Cable type | Ø cable (mm) | Collettore maggiorato |
5836/XF | 1 X | 2.5 | 15 | H05V-F | 5.5 | ||||
5834/XF | 1 X | 6 | 12.5 | H05V-F | 5.5 | * | |||
5832/XF. | 1 X | 16 | 8.5 | H05V-F | 8 | * | |||
5831/XF | 2 X | 1 | 14 | H05VV-F | 6 | ||||
5831/XF RNF | 2 X | 1 | 10 | 0.9 @230V | 1.4 @230V | H07RN-F | 8 | ||
5830/XF | 2 X | 1.5 | 11 | 1.1 @230V | 1.6 @230V | H05VV-F | 8 | ||
5829/XF | 2 X | 2.5 | 8.5 | 1.8 @230V | 2.3 @230V | H05VV-F | 9 | ||
5828/XF | 3 G | 1 | 12.5 | 0.9 @230V | 1.4 @230V | H05VV-F | 65 | ||
5827/XF | 3 G | 1.5 | 10 | 1.2 @230V | 1.8 @230V | H05VV-F | 7 | ||
5827/XF RNF | 3 G | 1.5 | 8 | 1.2 @230V | 1.8 @230V | H07RN-F | 95 | ||
5825/XF | 3 G | 2.5 | 7 | 1.9 @230V | 2.5 @230V | H05VV-F | 10 | ||
5826/XF | 3 G | 2.5 | 7 | 1.9 @230V | 2.5 @230V | H05VV-F | 10 | * | |
5824/XF | 4 G | 1 | 10.5 | 1.1 @400V | 1.6 @400V | H05VV-F | 7 | ||
5823/XF | 4 G | 1.5 | 8 | 1.4 @400V | 1.9 @400V | H05VV-F | 85 | ||
5821/XF | 4 G | 2.5 | 5.5 | 2 @400V | 2.7 @400V | H05VV-F | 11 | ||
5822/XF | 4 G | 2.5 | 5.5 | 2 @400V | 2.7 @400V | H05VV-F | 11 | * | |
5844/XF | 5 G | 1 | 7.5 | 1 @400V | 1.5 @400V | H05VV-F | 75 | ||
5843/XF | 5 G | 1.5 | 5.5 | 1.4 @400V | 1.9 @400V | H05VV-F | 95 | ||
5840/XF | 7 X | 1 | 6 | 3 | H05VV-F | 85 | |||
5839/XF | 7 X | 1.5 | 5.5 | 4.5 | H05VV-F | 105 | |||
5838/XF | 8 X | 1 | 5.5 | 3 | H05VV-F | 10 |
[specification] =>
ART. 5100
Conversion kit from XF in XL
ART. 949/5000
Optional device to make the fastening bracket of XF and XL series cable reels fixed instead of pivoting.
Ordering Manufacting P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Cable type | Ø cable (mm) | Collettore maggiorato |
5836/XF | 1 X | 2.5 | 15 | H05V-F | 5.5 | ||||
5834/XF | 1 X | 6 | 12.5 | H05V-F | 5.5 | * | |||
5832/XF. | 1 X | 16 | 8.5 | H05V-F | 8 | * | |||
5831/XF | 2 X | 1 | 14 | H05VV-F | 6 | ||||
5831/XF RNF | 2 X | 1 | 10 | 0.9 @230V | 1.4 @230V | H07RN-F | 8 | ||
5830/XF | 2 X | 1.5 | 11 | 1.1 @230V | 1.6 @230V | H05VV-F | 8 | ||
5829/XF | 2 X | 2.5 | 8.5 | 1.8 @230V | 2.3 @230V | H05VV-F | 9 | ||
5828/XF | 3 G | 1 | 12.5 | 0.9 @230V | 1.4 @230V | H05VV-F | 65 | ||
5827/XF | 3 G | 1.5 | 10 | 1.2 @230V | 1.8 @230V | H05VV-F | 7 | ||
5827/XF RNF | 3 G | 1.5 | 8 | 1.2 @230V | 1.8 @230V | H07RN-F | 95 | ||
5825/XF | 3 G | 2.5 | 7 | 1.9 @230V | 2.5 @230V | H05VV-F | 10 | ||
5826/XF | 3 G | 2.5 | 7 | 1.9 @230V | 2.5 @230V | H05VV-F | 10 | * | |
5824/XF | 4 G | 1 | 10.5 | 1.1 @400V | 1.6 @400V | H05VV-F | 7 | ||
5823/XF | 4 G | 1.5 | 8 | 1.4 @400V | 1.9 @400V | H05VV-F | 85 | ||
5821/XF | 4 G | 2.5 | 5.5 | 2 @400V | 2.7 @400V | H05VV-F | 11 | ||
5822/XF | 4 G | 2.5 | 5.5 | 2 @400V | 2.7 @400V | H05VV-F | 11 | * | |
5844/XF | 5 G | 1 | 7.5 | 1 @400V | 1.5 @400V | H05VV-F | 75 | ||
5843/XF | 5 G | 1.5 | 5.5 | 1.4 @400V | 1.9 @400V | H05VV-F | 95 | ||
5840/XF | 7 X | 1 | 6 | 3 | H05VV-F | 85 | |||
5839/XF | 7 X | 1.5 | 5.5 | 4.5 | H05VV-F | 105 | |||
5838/XF | 8 X | 1 | 5.5 | 3 | H05VV-F | 10 |
[12] => [applications] => [13] => [bgimage] => [14] => 1599026075Zeca_5000-XF_SERIES.pdf [file_name1] => 1599026075Zeca_5000-XF_SERIES.pdf [15] => [file_name2] => [16] => [file_name3] => [17] => [file_name4] => [18] => [file_name5] => [19] => [file_name6] => [20] => [file_name7] => [21] => [file_name8] => [22] => [file_name9] => [23] => [file_name10] => [24] => [file_name11] => [25] => [file_name12] => [26] => [file_name13] => [27] => [file_name14] => [28] => [file_name15] => [29] => [file_name16] => [30] => [file_name17] => [31] => [file_name18] => [32] => [file_name19] => [33] => [file_name20] => [34] => Zeca Series 500XF Cable reels [file_name1_name] => Zeca Series 500XF Cable reels [35] => [file_name2_name] => [36] => [file_name3_name] => [37] => [file_name4_name] => [38] => [file_name5_name] => [39] => [file_name6_name] => [40] => [file_name7_name] => [41] => [file_name8_name] => [42] => [file_name9_name] => [43] => [file_name10_name] => [44] => [file_name11_name] => [45] => [file_name12_name] => [46] => [file_name13_name] => [47] => [file_name14_name] => [48] => [file_name15_name] => [49] => [file_name16_name] => [50] => [file_name17_name] => [51] => [file_name18_name] => [52] => [file_name19_name] => [53] => [file_name20_name] => [54] => ZECA | Retractable Cable Reels [header_title] => ZECA | Retractable Cable Reels [55] => series 5000 XF [header_description] => series 5000 XF [56] => ZECA SEA Authorized Distributor [seometatitle] => ZECA SEA Authorized Distributor [57] => Spring return industrial electrical power cable reels for customer in Singapore Malaysia Indonesia Vietnam Thailand Philippines Cambodia Myanmar India Australia Taiwan China [seometadescription] => Spring return industrial electrical power cable reels for customer in Singapore Malaysia Indonesia Vietnam Thailand Philippines Cambodia Myanmar India Australia Taiwan China [58] => [ordern] => ) [2] => Array ( [0] => 352 [id] => 352 [1] => Zeca Series 500XL Industrial Electrical Power Cable Reels [title] => Zeca Series 500XL Industrial Electrical Power Cable Reels [2] => 332 [parent] => 332 [3] => Shock resistant plastic external case with rubber cable guide [description] => Shock resistant plastic external case with rubber cable guide [4] => 1 [status] => 1 [5] => 2020-09-02 00:22:24 [post_date] => 2020-09-02 00:22:24 [6] => 1599031341zeca_5000xl_cable_reels.jpg [image] => 1599031341zeca_5000xl_cable_reels.jpg [7] => [image2] => [8] => [image3] => [9] => [image4] => [10] => [image5] => [11] =>
ART. 949/5000
Optional device to make the fastened bracket. Essential for 7 and 8 set-ups
Ordering Manufacturing P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Cable type | Ø cable (mm) | Collettore maggiorato |
5897/XL . | 1 X | 2.5 | 15 | H05V-F | |||||
5894/XL . | 1 X | 16 | 8.5 | H05V-F | * | ||||
5896/XL . | 1 X | 6 | 12.5 | H05V-F | * | ||||
5880/XL . | 3 G | 2.5 | 7 | 1.9 @230V | 2.5 @230V | H05VV-F | 10 | * | |
5888/XL . | 3 G | 2.5 | 7 | 1.9 @230V | 2.5 @230V | H05VV-F | 10 | ||
5889/XL RNF . | 3 G | 1.5 | 7 | 1.2 @230V | 1.8 @230V | H07RN-F | 95 | ||
5890/XL RNF . | 3 G | 1 | 8 | 0.9 @230V | 1.4 @230V | H07RN-F | 9 | ||
5890/XL . | 3 G | 1 | 12.5 | 0.9 @230V | 1.4 @230V | H05VV-F | 65 | ||
5891/XL . | 2 X | 2.5 | 8.5 | 1.8 @230V | 2.3 @230V | H05VV-F | 9 | ||
5892/XL . | 2 X | 1.5 | 11 | 11 @230V | 1.6 @400V | H05VV-F | 8 | ||
5893/XL RNF . | 2 X | 1 | 10 | 0.9 @230V | 1.4 @230V | H07RN-F | 8 | ||
5893/XL . | 2 X | 1 | 14 | 0.9 @230V | 1.4 @230V | H05VV-F | 6 | ||
5877/XL . | 4 G | 1.5 | 8 | 1.4 @400V | 1.9 @400V | H05VV-F | 85 | ||
5876/XL . | 4 G | 2.5 | 5.5 | 2 @400V | 2.7 @400V | H05VV-F | 11 | ||
5878/XL . | 4 G | 1 | 10 | 1.1 @400V | 1.6 @400V | H05VV-F | 7 | ||
5899/XL . | 4 G | 2.5 | 5.5 | 2 @400V | 2.7 @400V | H05VV-F | 11 | * | |
5874/XL . | 5 G | 1.5 | 5.5+1.5 | 1.4 @400V | 1.9 @400V | 95 | |||
5870/XL . | 7 X | 1 | 6+1.5 | 3 | H05VV-F | 85 | |||
5869/XL . | 7 X | 1.5 | 5.5+1.5 | 4.5 | H05VV-F | 105 | |||
5868/XL . | 8 X | 1 | 5.5+1.5 | 3 | H05VV-F | 10 |
ART. 949/5000
Optional device to make the fastened bracket. Essential for 7 and 8 set-ups
Ordering Manufacturing P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Cable type | Ø cable (mm) | Collettore maggiorato |
5897/XL . | 1 X | 2.5 | 15 | H05V-F | |||||
5894/XL . | 1 X | 16 | 8.5 | H05V-F | * | ||||
5896/XL . | 1 X | 6 | 12.5 | H05V-F | * | ||||
5880/XL . | 3 G | 2.5 | 7 | 1.9 @230V | 2.5 @230V | H05VV-F | 10 | * | |
5888/XL . | 3 G | 2.5 | 7 | 1.9 @230V | 2.5 @230V | H05VV-F | 10 | ||
5889/XL RNF . | 3 G | 1.5 | 7 | 1.2 @230V | 1.8 @230V | H07RN-F | 95 | ||
5890/XL RNF . | 3 G | 1 | 8 | 0.9 @230V | 1.4 @230V | H07RN-F | 9 | ||
5890/XL . | 3 G | 1 | 12.5 | 0.9 @230V | 1.4 @230V | H05VV-F | 65 | ||
5891/XL . | 2 X | 2.5 | 8.5 | 1.8 @230V | 2.3 @230V | H05VV-F | 9 | ||
5892/XL . | 2 X | 1.5 | 11 | 11 @230V | 1.6 @400V | H05VV-F | 8 | ||
5893/XL RNF . | 2 X | 1 | 10 | 0.9 @230V | 1.4 @230V | H07RN-F | 8 | ||
5893/XL . | 2 X | 1 | 14 | 0.9 @230V | 1.4 @230V | H05VV-F | 6 | ||
5877/XL . | 4 G | 1.5 | 8 | 1.4 @400V | 1.9 @400V | H05VV-F | 85 | ||
5876/XL . | 4 G | 2.5 | 5.5 | 2 @400V | 2.7 @400V | H05VV-F | 11 | ||
5878/XL . | 4 G | 1 | 10 | 1.1 @400V | 1.6 @400V | H05VV-F | 7 | ||
5899/XL . | 4 G | 2.5 | 5.5 | 2 @400V | 2.7 @400V | H05VV-F | 11 | * | |
5874/XL . | 5 G | 1.5 | 5.5+1.5 | 1.4 @400V | 1.9 @400V | 95 | |||
5870/XL . | 7 X | 1 | 6+1.5 | 3 | H05VV-F | 85 | |||
5869/XL . | 7 X | 1.5 | 5.5+1.5 | 4.5 | H05VV-F | 105 | |||
5868/XL . | 8 X | 1 | 5.5+1.5 | 3 | H05VV-F | 10 |
ART. 949/804-4000
Optional device to make the bracket fastened.
Ordering Manufacturing P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Cable type | Ø cable (mm) |
4106 | 1 X | 6 | 16 | H05V-F | 55 | ||
4116 | 1 X | 16 | 8 | H05V-F | 8 | ||
4325/15 | 3 G | 2.5 | 14+1 | Igus CF900 | 85 | ||
4210 | 2 X | 1 | 18 | 0.9 @230V | 1.4 @230V | H05VV-F | 6 |
4210 RNF | 2 X | 1 | 13 | 0.9 @230V | 1.4 @230V | H07RN-F | 8 |
4215 | 2 X | 1.5 | 16 | 1.1 @230V | 1.6 @230V | H05VV-F | 8 |
4315 | 3 G | 1.5 | 15 | 1.2 @230V | 1.8 @230V | H05VV-F | 7 |
4315 RNF | 3 G | 1.5 | 10 | 1.2 @230V | 1.8 @230V | H07RN-F | 95 |
4325 | 3 G | 2.5 | 10 | 1.9 @230V | 2.5 @230V | H05VV-F | 10 |
4325 RNF | 3 G | 2.5 | 8 | 1.9 @230V | 2.5 @230V | H07RN-F | 115 |
4415 | 4 G | 1.5 | 11 | 1.4 @400V | 1.9 @400V | H05VV-F | 85 |
4415 RNF | 4 G | 1.5 | 9 | 1.4 @400V | 1.9 @400V | H07RN-F | 105 |
4425 | 4 G | 2.5 | 9 | 2 @400V | 2.7 @400V | H05VV-F | 11 |
4425 RNF | 4 G | 2.5 | 6 | 2 @400V | 2.7 @400V | H07RN-F | 125 |
4510 | 5 G | 1 | 10.5+1 | 1 @400V | 1.5 @400V | H05VV-F | 75 |
4515 | 5 G | 1.5 | 9 | 1.4 @400V | 1.9 @400V | H05VV-F | 95 |
4515 RNF | 5 G | 1.5 | 8 | 1.4 @400V | 1.9 @400V | H07RN-F | 12 |
ART. 949/804-4000
Optional device to make the bracket fastened.
Ordering Manufacturing P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Cable type | Ø cable (mm) |
4106 | 1 X | 6 | 16 | H05V-F | 55 | ||
4116 | 1 X | 16 | 8 | H05V-F | 8 | ||
4325/15 | 3 G | 2.5 | 14+1 | Igus CF900 | 85 | ||
4210 | 2 X | 1 | 18 | 0.9 @230V | 1.4 @230V | H05VV-F | 6 |
4210 RNF | 2 X | 1 | 13 | 0.9 @230V | 1.4 @230V | H07RN-F | 8 |
4215 | 2 X | 1.5 | 16 | 1.1 @230V | 1.6 @230V | H05VV-F | 8 |
4315 | 3 G | 1.5 | 15 | 1.2 @230V | 1.8 @230V | H05VV-F | 7 |
4315 RNF | 3 G | 1.5 | 10 | 1.2 @230V | 1.8 @230V | H07RN-F | 95 |
4325 | 3 G | 2.5 | 10 | 1.9 @230V | 2.5 @230V | H05VV-F | 10 |
4325 RNF | 3 G | 2.5 | 8 | 1.9 @230V | 2.5 @230V | H07RN-F | 115 |
4415 | 4 G | 1.5 | 11 | 1.4 @400V | 1.9 @400V | H05VV-F | 85 |
4415 RNF | 4 G | 1.5 | 9 | 1.4 @400V | 1.9 @400V | H07RN-F | 105 |
4425 | 4 G | 2.5 | 9 | 2 @400V | 2.7 @400V | H05VV-F | 11 |
4425 RNF | 4 G | 2.5 | 6 | 2 @400V | 2.7 @400V | H07RN-F | 125 |
4510 | 5 G | 1 | 10.5+1 | 1 @400V | 1.5 @400V | H05VV-F | 75 |
4515 | 5 G | 1.5 | 9 | 1.4 @400V | 1.9 @400V | H05VV-F | 95 |
4515 RNF | 5 G | 1.5 | 8 | 1.4 @400V | 1.9 @400V | H07RN-F | 12 |
ART. 949/805-7000
Optional device to make the fastening bracket fixed instead of pivoting. Essential for ceiling installation.
ART. 7000/SR
Ordering Manufacturing P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Cable type | Ø cable (mm) |
7116 | 1 X | 16 | 22 | H05V-F | 8 | ||
7215 | 2 X | 1.5 | 27 | 1.1 @230V | 1.8 @230V | H05VV-F | 8 |
7315 | 3 G | 1.5 | 27 | 1.1 @230V | 1.8 @230V | H05VV-F | 7 |
7315 RNF | 3 G | 1.5 | 22 | 1.1 @230V | 1.8 @230V | H07RN-F | 95 |
7325 | 3 G | 2.5 | 22 | 2 @230V | 3 @230V | H05VV-F | 10 |
7325/25 | 3 G | 2.5 | 23+2 | 2 @230V | 3 @230V | Igus CF900 | 85 |
7325 RNF | 3 G | 2.5 | 19 | 2 @230V | 3 @230V | H07RN-F | 115 |
7415 | 4 G | 1.5 | 27 | 1.1 @400V | 1.8 @400V | H05VV-F | 85 |
7415 RNF | 4 G | 1.5 | 18 | 1.1 @400V | 1.8 @400V | H07RN-F | 105 |
7425 | 4 G | 2.5 | 20 | 2 @400V | 3 @400V | H05VV-F | 11 |
7425 RNF | 4 G | 2.5 | 15 | 2 @400V | 3 @400V | H07RN-F | 125 |
7515 | 5 G | 1.5 | 22 | 1.5 @400V | 2.2 @400V | H05VV-F | 95 |
7515 RNF | 5 G | 1.5 | 17 | 1.5 @400V | 2.2 @400V | H07RN-F | 12 |
7525 | 5 G | 2.5 | 17 | 2 @400V | 3 @400V | H05VV-F | 125 |
7525 RNF | 5 G | 2.5 | 12 | 2 @400V | 3 @400V | H07RN-F | 135 |
ART. 949/805-7000
Optional device to make the fastening bracket fixed instead of pivoting. Essential for ceiling installation.
ART. 7000/SR
Ordering Manufacturing P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Cable type | Ø cable (mm) |
7116 | 1 X | 16 | 22 | H05V-F | 8 | ||
7215 | 2 X | 1.5 | 27 | 1.1 @230V | 1.8 @230V | H05VV-F | 8 |
7315 | 3 G | 1.5 | 27 | 1.1 @230V | 1.8 @230V | H05VV-F | 7 |
7315 RNF | 3 G | 1.5 | 22 | 1.1 @230V | 1.8 @230V | H07RN-F | 95 |
7325 | 3 G | 2.5 | 22 | 2 @230V | 3 @230V | H05VV-F | 10 |
7325/25 | 3 G | 2.5 | 23+2 | 2 @230V | 3 @230V | Igus CF900 | 85 |
7325 RNF | 3 G | 2.5 | 19 | 2 @230V | 3 @230V | H07RN-F | 115 |
7415 | 4 G | 1.5 | 27 | 1.1 @400V | 1.8 @400V | H05VV-F | 85 |
7415 RNF | 4 G | 1.5 | 18 | 1.1 @400V | 1.8 @400V | H07RN-F | 105 |
7425 | 4 G | 2.5 | 20 | 2 @400V | 3 @400V | H05VV-F | 11 |
7425 RNF | 4 G | 2.5 | 15 | 2 @400V | 3 @400V | H07RN-F | 125 |
7515 | 5 G | 1.5 | 22 | 1.5 @400V | 2.2 @400V | H05VV-F | 95 |
7515 RNF | 5 G | 1.5 | 17 | 1.5 @400V | 2.2 @400V | H07RN-F | 12 |
7525 | 5 G | 2.5 | 17 | 2 @400V | 3 @400V | H05VV-F | 125 |
7525 RNF | 5 G | 2.5 | 12 | 2 @400V | 3 @400V | H07RN-F | 135 |
ART. 953
Roller cable-guide for cable reels PR series. Essential for ceiling applications.
ART. 6100
PRC to PRL conversion kit.
ART. 949/PR
Optional device to make the bracket fastened.
Ordering Manufacturing P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Cable type | Ø cable (mm) | Collettore maggiorato |
6198/PRC . | 1 X | 2.5 | 30 | H05V-F | 5.5 | ||||
6195/PRC . | 1 X | 6 | 26 | H05V-F | 5.5 | * | |||
6193/PRC . | 1 X | 16 | 17 | H05V-F | 8 | * | |||
6183/PRC . | 3 G | 2.5 | 20+2 | Igus CF900 | 85 | ||||
6188/PRC . | 3 G | 2.5 | 20+2 | Igus CF900 | 85 | ||||
6175/PRC . | 2 X | 1 | 20 | 1 @230V | 1.7 @230V | H05VV-F | 6 | ||
6192/PRC . | 2 X | 1 | 26 | 1 @230V | 1.7 @230V | H05VV-F | 6 | ||
6191/PRC . | 2 X | 1.5 | 26 | 1.1 @230V | 1.8 @230V | H05VV-F | 8 | ||
6189/PRC . | 2 X | 2.5 | 23 | 1.8 @230V | 2.5 @230V | H05VV-F | 9 | ||
6187/PRC . | 3 G | 1 | 26 | 1 @230V | 1.7 @230V | H05VV-F | 65 | ||
6186/PRC . | 3 G | 1.5 | 26 | 1.8 @230V | 1.8 @400V | H05VV-F | 7 | ||
6186/PRC RNF . | 3 G | 1.5 | 22 | 1.1 @230V | 1.8 @400V | H07RN-F | 95 | ||
6184/PRC . | 3 G | 2.5 | 17 | 1.1 @400V | 3 @230V | H05VV-F | 10 | ||
6185/PRC . | 3 G | 2.5 | 17 | 2 @230V | 3 @230V | H05VV-F | 10 | * | |
6184/PRC RNF . | 3 G | 2.5 | 14 | 2 @230V | 3 @230V | H05VV-F | 115 | ||
6185/PRC RNF . | 3 G | 2.5 | 14 | 2 @230V | 3 @230V | H07RN-F | 115 | * | |
6182/PRC . | 4 G | 1 | 26 | 2 @400V | 1.4 @400V | H05VV-F | 7 | ||
6181/PRC . | 4 G | 1.5 | 23 | 2 @400V | 1.8 @400V | H05VV-F | 85 | ||
6181/PRC RNF . | 4 G | 1.5 | 18 | 2 @400V | 1.8 @400V | H07RN-F | 105 | ||
6179/PRC . | 4 G | 2.5 | 17 | 1.5 @400V | 3 @400V | H05VV-F | 11 | ||
6521/PRC . | 4 G | 2.5 | 17 | 0.8 @400V | 3 @400V | H05VV-F | 11 | * | |
6521/PRC RNF . | 4 G | 2.5 | 12 | 2 @400V | 3 @400V | H07RN-F | 125 | * | |
6458/PRC . | 4 G | 4 | 10 | 2 @400V | 4 @400V | H05VV-F | 14 | * | |
6063/PRC . | 5 G | 1 | 18 | 2 @400V | 1.4 @400V | H05VV-F | 75 | ||
6067/PRC . | 5 G | 1.5 | 17 | 1.1 @400V | 2.2 @400V | H05VV-F | 95 | ||
6022/PRC . | 5 G | 2.5 | 12 | 1.1 @400V | 3 @400V | H05VV-F | 125 | ||
6068/PRC . | 5 G | 2.5 | 12 | 0.8 @400V | 3 @400V | H05VV-F | 125 | * | |
6068/PRC RNF . | 5 G | 2.5 | 10 | 2 @230V | 3 @400V | H07RN-F | 135 | * | |
6065/PRC . | 7 X | 1 | 18 | 3 | H05VV-F | 85 | |||
6069/PRC . | 7 X | 1.5 | 11 | 4.5 | H05VV-F | 105 | |||
6066/PRC . | 8 X | 1 | 13 | 3 | H05VV-F | 10 | |||
6070/PRC . | 8 X | 1.5 | 10 | 4.5 | H05VV-F | 115 | |||
6061/PRC . | 8 X | 2.5 | 8 | 7.5 | H05VV-F | 14 | |||
6095/PRC . | 10 X | 1 | 10 | 3 | H05VV-F | 13 | |||
6591/PRC . | 12 X | 1 | 12 | 3 | H05VV-F | 13 | |||
6619/PRC . | 10 X | 1.5 | 8 | 4.5 | H05VV-F | 155 | |||
6593/PRC . | 12 X | 1.5 | 8 | 4.5 | H05VV-F | 135 | |||
6096/PRC . | 16 X | 1 | 8 | 3 | H05VV-F | 14 |
ART. 953
Roller cable-guide for cable reels PR series. Essential for ceiling applications.
ART. 6100
PRC to PRL conversion kit.
ART. 949/PR
Optional device to make the bracket fastened.
Ordering Manufacturing P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Cable type | Ø cable (mm) | Collettore maggiorato |
6198/PRC . | 1 X | 2.5 | 30 | H05V-F | 5.5 | ||||
6195/PRC . | 1 X | 6 | 26 | H05V-F | 5.5 | * | |||
6193/PRC . | 1 X | 16 | 17 | H05V-F | 8 | * | |||
6183/PRC . | 3 G | 2.5 | 20+2 | Igus CF900 | 85 | ||||
6188/PRC . | 3 G | 2.5 | 20+2 | Igus CF900 | 85 | ||||
6175/PRC . | 2 X | 1 | 20 | 1 @230V | 1.7 @230V | H05VV-F | 6 | ||
6192/PRC . | 2 X | 1 | 26 | 1 @230V | 1.7 @230V | H05VV-F | 6 | ||
6191/PRC . | 2 X | 1.5 | 26 | 1.1 @230V | 1.8 @230V | H05VV-F | 8 | ||
6189/PRC . | 2 X | 2.5 | 23 | 1.8 @230V | 2.5 @230V | H05VV-F | 9 | ||
6187/PRC . | 3 G | 1 | 26 | 1 @230V | 1.7 @230V | H05VV-F | 65 | ||
6186/PRC . | 3 G | 1.5 | 26 | 1.8 @230V | 1.8 @400V | H05VV-F | 7 | ||
6186/PRC RNF . | 3 G | 1.5 | 22 | 1.1 @230V | 1.8 @400V | H07RN-F | 95 | ||
6184/PRC . | 3 G | 2.5 | 17 | 1.1 @400V | 3 @230V | H05VV-F | 10 | ||
6185/PRC . | 3 G | 2.5 | 17 | 2 @230V | 3 @230V | H05VV-F | 10 | * | |
6184/PRC RNF . | 3 G | 2.5 | 14 | 2 @230V | 3 @230V | H05VV-F | 115 | ||
6185/PRC RNF . | 3 G | 2.5 | 14 | 2 @230V | 3 @230V | H07RN-F | 115 | * | |
6182/PRC . | 4 G | 1 | 26 | 2 @400V | 1.4 @400V | H05VV-F | 7 | ||
6181/PRC . | 4 G | 1.5 | 23 | 2 @400V | 1.8 @400V | H05VV-F | 85 | ||
6181/PRC RNF . | 4 G | 1.5 | 18 | 2 @400V | 1.8 @400V | H07RN-F | 105 | ||
6179/PRC . | 4 G | 2.5 | 17 | 1.5 @400V | 3 @400V | H05VV-F | 11 | ||
6521/PRC . | 4 G | 2.5 | 17 | 0.8 @400V | 3 @400V | H05VV-F | 11 | * | |
6521/PRC RNF . | 4 G | 2.5 | 12 | 2 @400V | 3 @400V | H07RN-F | 125 | * | |
6458/PRC . | 4 G | 4 | 10 | 2 @400V | 4 @400V | H05VV-F | 14 | * | |
6063/PRC . | 5 G | 1 | 18 | 2 @400V | 1.4 @400V | H05VV-F | 75 | ||
6067/PRC . | 5 G | 1.5 | 17 | 1.1 @400V | 2.2 @400V | H05VV-F | 95 | ||
6022/PRC . | 5 G | 2.5 | 12 | 1.1 @400V | 3 @400V | H05VV-F | 125 | ||
6068/PRC . | 5 G | 2.5 | 12 | 0.8 @400V | 3 @400V | H05VV-F | 125 | * | |
6068/PRC RNF . | 5 G | 2.5 | 10 | 2 @230V | 3 @400V | H07RN-F | 135 | * | |
6065/PRC . | 7 X | 1 | 18 | 3 | H05VV-F | 85 | |||
6069/PRC . | 7 X | 1.5 | 11 | 4.5 | H05VV-F | 105 | |||
6066/PRC . | 8 X | 1 | 13 | 3 | H05VV-F | 10 | |||
6070/PRC . | 8 X | 1.5 | 10 | 4.5 | H05VV-F | 115 | |||
6061/PRC . | 8 X | 2.5 | 8 | 7.5 | H05VV-F | 14 | |||
6095/PRC . | 10 X | 1 | 10 | 3 | H05VV-F | 13 | |||
6591/PRC . | 12 X | 1 | 12 | 3 | H05VV-F | 13 | |||
6619/PRC . | 10 X | 1.5 | 8 | 4.5 | H05VV-F | 155 | |||
6593/PRC . | 12 X | 1.5 | 8 | 4.5 | H05VV-F | 135 | |||
6096/PRC . | 16 X | 1 | 8 | 3 | H05VV-F | 14 |
ART. 949/PR
Optional device to make the fastening bracket of PRC series cable reels fixed instead of pivoting.
Ordering Manufacturing P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Cable type | Ø cable (mm) | Collettore maggiorato |
6340/PRL | 1 X | 2.5 | 30 | H05V-F | 5.5 | ||||
6386/PRL | 1 X | 6 | 26 | H05V-F | 5.5 | * | |||
6384/PRL | 1 X | 16 | 17 | H05V-F | 8 | * | |||
6341/PRL | 2 X | 1 | 20 | 1 @230V | 1.7 @230V | 1 | H05VV-F | 6 | |
6383/PRL | 2 X | 1 | 26 | 1 @230V | 1.7 @230V | 1 | H05VV-F | 6 | |
6382/PRL | 2 X | 1.5 | 26 | 1.1 @230V | 1.8 @230V | 1.1 | H05VV-F | 8 | |
6380/PRL | 2 X | 2.5 | 23 | 1.8 @230V | 2.5 @230V | 1.8 | H05VV-F | 9 | |
6378/PRL | 3 G | 1 | 26 | 1 @230V | 1.7 @230V | 1 | H05VV-F | 65 | |
6377/PRL | 3 G | 1.5 | 26 | 1.1 @230V | 1.8 @230V | 1.1 | H05VV-F | 7 | |
6377/PRL RNF | 3 G | 1.5 | 22 | 1.1 @230V | 1.8 @230V | 1.1 | H07RN-F | 95 | |
6375/PRL | 3 G | 2.5 | 17 | 2 @230V | 3 @230V | 2 | H05VV-F | 10 | |
6376/PRL | 3 G | 2.5 | 17 | 2 @230V | 3 @230V | 2 | H05VV-F | 10 | * |
6375/PRL RNF | 3 G | 2.5 | 14 | 2 @230V | 3 @230V | 2 | H07RN-F | 115 | |
6376/PRL RNF | 3 G | 2.5 | 14 | 2 @230V | 3 @230V | 2 | H07RN-F | 115 | * |
6373/PRL | 4 G | 1 | 26 | 0.8 @400V | 1.4 @400V | 0.8 | H05VV-F | 7 | |
6372/PRL | 4 G | 1.5 | 23 | 1.1 @400V | 1.8 @400V | 1.1 | H05VV-F | 85 | |
6372/PRL RNF | 4 G | 1.5 | 18 | 1.1 @400V | 1.8 @400V | 1.1 | H07RN-F | 105 | |
6370/PRL | 4 G | 2.5 | 17 | 2 @400V | 3 @400V | 2 | H05VV-F | 11 | |
6525/PRL | 4 G | 2.5 | 17 | 2 @400V | 3 @400V | 2 | H05VV-F | 11 | * |
6525/PRL RNF | 4 G | 2.5 | 12 | 2 @400V | 3 @400V | 2 | H07RN-F | 125 | * |
6396/PRL | 4 G | 4 | 10 | 3 @400V | 4 @400V | H05VV-F | 14 | * | |
6136/PRL | 5 G | 1 | 18 | 0.8 @400V | 1.4 @400V | 0.8 | H05VV-F | 75 | |
6140/PRL | 5 G | 1.5 | 17 | 1.5 @400V | 2.2 @400V | 1.5 | H05VV-F | 95 | |
6154/PRL | 5 G | 2.5 | 12 | 2 @400V | 3 @400V | 2 | H05VV-F | 12.5 | |
6156/PRL | 5 G | 2.5 | 12 | 2 @400V | 3 @400V | 2 | H05VV-F | 12.5 | * |
6156/PRL RNF | 5 G | 2.5 | 10 | 2 @400V | 3 @400V | 2 | H07RN-F | 135 | * |
6138/PRL | 7 X | 1 | 18 | 3 | H05VV-F | 85 | |||
6142/PRL | 7 X | 1.5 | 11 | 4.5 | H05VV-F | 105 | |||
6139/PRL | 8 X | 1 | 13 | 3 | H05VV-F | 10 | |||
6143/PRL | 8 X | 1.5 | 10 | 4.5 | H05VV-F | 115 | |||
6196/PRL | 8 X | 2.5 | 8 | 7.5 | H05VV-F | 14 | |||
6144/PRL | 10 X | 1 | 10 | 3 | H05VV-F | 13 | |||
6146/PRL | 10 X | 1.5 | 8 | 4.5 | H05VV-F | 155 | |||
6614/PRL | 12 X | 1 | 12 | 3 | H05VV-F | 13 | |||
6616/PRL | 12 X | 1.5 | 8 | 4.5 | H05VV-F | 135 | |||
6145/PRL | 16 X | 1 | 8 | 3 | H05VV-F | 14 |
ART. 949/PR
Optional device to make the fastening bracket of PRC series cable reels fixed instead of pivoting.
Ordering Manufacturing P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Cable type | Ø cable (mm) | Collettore maggiorato |
6340/PRL | 1 X | 2.5 | 30 | H05V-F | 5.5 | ||||
6386/PRL | 1 X | 6 | 26 | H05V-F | 5.5 | * | |||
6384/PRL | 1 X | 16 | 17 | H05V-F | 8 | * | |||
6341/PRL | 2 X | 1 | 20 | 1 @230V | 1.7 @230V | 1 | H05VV-F | 6 | |
6383/PRL | 2 X | 1 | 26 | 1 @230V | 1.7 @230V | 1 | H05VV-F | 6 | |
6382/PRL | 2 X | 1.5 | 26 | 1.1 @230V | 1.8 @230V | 1.1 | H05VV-F | 8 | |
6380/PRL | 2 X | 2.5 | 23 | 1.8 @230V | 2.5 @230V | 1.8 | H05VV-F | 9 | |
6378/PRL | 3 G | 1 | 26 | 1 @230V | 1.7 @230V | 1 | H05VV-F | 65 | |
6377/PRL | 3 G | 1.5 | 26 | 1.1 @230V | 1.8 @230V | 1.1 | H05VV-F | 7 | |
6377/PRL RNF | 3 G | 1.5 | 22 | 1.1 @230V | 1.8 @230V | 1.1 | H07RN-F | 95 | |
6375/PRL | 3 G | 2.5 | 17 | 2 @230V | 3 @230V | 2 | H05VV-F | 10 | |
6376/PRL | 3 G | 2.5 | 17 | 2 @230V | 3 @230V | 2 | H05VV-F | 10 | * |
6375/PRL RNF | 3 G | 2.5 | 14 | 2 @230V | 3 @230V | 2 | H07RN-F | 115 | |
6376/PRL RNF | 3 G | 2.5 | 14 | 2 @230V | 3 @230V | 2 | H07RN-F | 115 | * |
6373/PRL | 4 G | 1 | 26 | 0.8 @400V | 1.4 @400V | 0.8 | H05VV-F | 7 | |
6372/PRL | 4 G | 1.5 | 23 | 1.1 @400V | 1.8 @400V | 1.1 | H05VV-F | 85 | |
6372/PRL RNF | 4 G | 1.5 | 18 | 1.1 @400V | 1.8 @400V | 1.1 | H07RN-F | 105 | |
6370/PRL | 4 G | 2.5 | 17 | 2 @400V | 3 @400V | 2 | H05VV-F | 11 | |
6525/PRL | 4 G | 2.5 | 17 | 2 @400V | 3 @400V | 2 | H05VV-F | 11 | * |
6525/PRL RNF | 4 G | 2.5 | 12 | 2 @400V | 3 @400V | 2 | H07RN-F | 125 | * |
6396/PRL | 4 G | 4 | 10 | 3 @400V | 4 @400V | H05VV-F | 14 | * | |
6136/PRL | 5 G | 1 | 18 | 0.8 @400V | 1.4 @400V | 0.8 | H05VV-F | 75 | |
6140/PRL | 5 G | 1.5 | 17 | 1.5 @400V | 2.2 @400V | 1.5 | H05VV-F | 95 | |
6154/PRL | 5 G | 2.5 | 12 | 2 @400V | 3 @400V | 2 | H05VV-F | 12.5 | |
6156/PRL | 5 G | 2.5 | 12 | 2 @400V | 3 @400V | 2 | H05VV-F | 12.5 | * |
6156/PRL RNF | 5 G | 2.5 | 10 | 2 @400V | 3 @400V | 2 | H07RN-F | 135 | * |
6138/PRL | 7 X | 1 | 18 | 3 | H05VV-F | 85 | |||
6142/PRL | 7 X | 1.5 | 11 | 4.5 | H05VV-F | 105 | |||
6139/PRL | 8 X | 1 | 13 | 3 | H05VV-F | 10 | |||
6143/PRL | 8 X | 1.5 | 10 | 4.5 | H05VV-F | 115 | |||
6196/PRL | 8 X | 2.5 | 8 | 7.5 | H05VV-F | 14 | |||
6144/PRL | 10 X | 1 | 10 | 3 | H05VV-F | 13 | |||
6146/PRL | 10 X | 1.5 | 8 | 4.5 | H05VV-F | 155 | |||
6614/PRL | 12 X | 1 | 12 | 3 | H05VV-F | 13 | |||
6616/PRL | 12 X | 1.5 | 8 | 4.5 | H05VV-F | 135 | |||
6145/PRL | 16 X | 1 | 8 | 3 | H05VV-F | 14 |
ART 953
Roller cable-guide for cable reels PR series. Essential for ceiling applications.
ART 6100
PRC to PRL conversion kit.
ART 949/PR
Optional device to make the fastening bracket of PRC series cable reels fixed instead of pivoting
Ordering Manufacturing P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Cable type | Ø cable (mm) | Collettore maggiorato |
6195/PRC/IP65 | 1 X | 6 | 26 | H05V-F | 5.5 | * | |||
6193/PRC/IP65 | 1 X | 16 | 17 | H05V-F | 8 | * | |||
6192/PRC/IP65 | 2 X | 1 | 26 | 1 @230V | 1.7 @230V | H05VV-F | 6 | ||
6191/PRC/IP65 | 2 X | 1.5 | 26 | 1.1 @230V | 1.8 @230V | H05VV-F | 8 | ||
6189/PRC/IP65 | 2 X | 2.5 | 23 | 1.8 @230V | 2.5 @230V | H05VV-F | 9 | ||
6190/PRC/IP65 | 2 X | 2.5 | 23 | 1.8 @230V | 2.5 @230V | H05VV-F | 9 | * | |
6187/PRC/IP65 | 3 G | 1 | 26 | 1 @230V | 1.7 @230V | H05VV-F | 65 | ||
6186/PRC/IP65 | 3 G | 1.5 | 26 | 1.1 @230V | 1.8 @230V | H07RN-F | 8.5 | ||
6182/PRC/IP65 | 4 G | 1 | 24+2 | 1.1 @230V | 1.4 @400V | H05VV-F | 7 | ||
6181/PRC/IP65 | 4 G | 1.5 | 21+2 | 2 @230V | 1.8 @400V | H05VV-F | 85 | ||
6186/IP65 RNF | 3 G | 1.5 | 22 | 2 @230V | 1.8 @230V | H07RN-F | 95 | ||
6181/IP65 RNF | 4 G | 1.5 | 16+2 | 2 @230V | 1.8 @400V | H05VV-F | 105 | ||
6179/PRC/IP65 | 4 G | 2.5 | 15+2 | 2 @230V | 3 @400V | H07RN-F | 11 | ||
6184/PRC/IP65 | 3 G | 2.5 | 17 | 1.1 @230V | 3 @230V | H05VV-F | 10 | ||
6521/PRC/IP65 | 4 G | 2.5 | 15+2 | 0.8 @400V | 3 @400V | H05VV-F | 11 | * | |
6179/IP65 RNF | 4 G | 2.5 | 10+2 | 1.1 @230V | 3 @400V | H07RN-F | 125 | ||
6185/PRC/IP65 | 3 G | 2.5 | 17 | 2 @400V | 3 @230V | H05VV-F | 10 | * | |
6521/IP65 RNF | 4 G | 2.5 | 10+2 | 2 @400V | 3 @400V | H05VV-F | 125 | * | |
6063/PRC/IP65 | 5 G | 1 | 16+2 | 2 @400V | 1.4 @400V | H07RN-F | 75 | ||
6184/IP65 RNF | 3 G | 2.5 | 14 | 0.8 @400V | 3 @230V | H05VV-F | 115 | ||
6067/PRC/IP65 | 5 G | 1.5 | 15+2 | 2 @400V | 2.2 @400V | H07RN-F | 95 | ||
6022/PRC/IP65 | 5 G | 2.5 | 10+2 | 1.5 @400V | 3 @400V | H05VV-F | 125 | ||
6185/IP65 RNF | 3 G | 2.5 | 14 | 2 @400V | 3 @230V | H07RN-F | 115 | * | |
6022/IP65 RNF | 5 G | 2.5 | 8+2 | 2 @400V | 3 @400V | H05VV-F | 135 | ||
6065/PRC/IP65 | 7 X | 1 | 16+2 | 3 | H05VV-F | 85 | |||
6069/PRC/IP65 | 7 X | 1.5 | 9+2 | 4.5 | H05VV-F | 105 | |||
6066/PRC/IP65 | 8 X | 1 | 11+2 | 3 | H05VV-F | 10 | |||
6070/PRC/IP65 | 8 X | 1.5 | 8+2 | 4.5 | H05VV-F | 115 |
ART 953
Roller cable-guide for cable reels PR series. Essential for ceiling applications.
ART 6100
PRC to PRL conversion kit.
ART 949/PR
Optional device to make the fastening bracket of PRC series cable reels fixed instead of pivoting
Ordering Manufacturing P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Cable type | Ø cable (mm) | Collettore maggiorato |
6195/PRC/IP65 | 1 X | 6 | 26 | H05V-F | 5.5 | * | |||
6193/PRC/IP65 | 1 X | 16 | 17 | H05V-F | 8 | * | |||
6192/PRC/IP65 | 2 X | 1 | 26 | 1 @230V | 1.7 @230V | H05VV-F | 6 | ||
6191/PRC/IP65 | 2 X | 1.5 | 26 | 1.1 @230V | 1.8 @230V | H05VV-F | 8 | ||
6189/PRC/IP65 | 2 X | 2.5 | 23 | 1.8 @230V | 2.5 @230V | H05VV-F | 9 | ||
6190/PRC/IP65 | 2 X | 2.5 | 23 | 1.8 @230V | 2.5 @230V | H05VV-F | 9 | * | |
6187/PRC/IP65 | 3 G | 1 | 26 | 1 @230V | 1.7 @230V | H05VV-F | 65 | ||
6186/PRC/IP65 | 3 G | 1.5 | 26 | 1.1 @230V | 1.8 @230V | H07RN-F | 8.5 | ||
6182/PRC/IP65 | 4 G | 1 | 24+2 | 1.1 @230V | 1.4 @400V | H05VV-F | 7 | ||
6181/PRC/IP65 | 4 G | 1.5 | 21+2 | 2 @230V | 1.8 @400V | H05VV-F | 85 | ||
6186/IP65 RNF | 3 G | 1.5 | 22 | 2 @230V | 1.8 @230V | H07RN-F | 95 | ||
6181/IP65 RNF | 4 G | 1.5 | 16+2 | 2 @230V | 1.8 @400V | H05VV-F | 105 | ||
6179/PRC/IP65 | 4 G | 2.5 | 15+2 | 2 @230V | 3 @400V | H07RN-F | 11 | ||
6184/PRC/IP65 | 3 G | 2.5 | 17 | 1.1 @230V | 3 @230V | H05VV-F | 10 | ||
6521/PRC/IP65 | 4 G | 2.5 | 15+2 | 0.8 @400V | 3 @400V | H05VV-F | 11 | * | |
6179/IP65 RNF | 4 G | 2.5 | 10+2 | 1.1 @230V | 3 @400V | H07RN-F | 125 | ||
6185/PRC/IP65 | 3 G | 2.5 | 17 | 2 @400V | 3 @230V | H05VV-F | 10 | * | |
6521/IP65 RNF | 4 G | 2.5 | 10+2 | 2 @400V | 3 @400V | H05VV-F | 125 | * | |
6063/PRC/IP65 | 5 G | 1 | 16+2 | 2 @400V | 1.4 @400V | H07RN-F | 75 | ||
6184/IP65 RNF | 3 G | 2.5 | 14 | 0.8 @400V | 3 @230V | H05VV-F | 115 | ||
6067/PRC/IP65 | 5 G | 1.5 | 15+2 | 2 @400V | 2.2 @400V | H07RN-F | 95 | ||
6022/PRC/IP65 | 5 G | 2.5 | 10+2 | 1.5 @400V | 3 @400V | H05VV-F | 125 | ||
6185/IP65 RNF | 3 G | 2.5 | 14 | 2 @400V | 3 @230V | H07RN-F | 115 | * | |
6022/IP65 RNF | 5 G | 2.5 | 8+2 | 2 @400V | 3 @400V | H05VV-F | 135 | ||
6065/PRC/IP65 | 7 X | 1 | 16+2 | 3 | H05VV-F | 85 | |||
6069/PRC/IP65 | 7 X | 1.5 | 9+2 | 4.5 | H05VV-F | 105 | |||
6066/PRC/IP65 | 8 X | 1 | 11+2 | 3 | H05VV-F | 10 | |||
6070/PRC/IP65 | 8 X | 1.5 | 8+2 | 4.5 | H05VV-F | 115 |
ART 953
Roller cable-guide for cable reels PR series. Essential for ceiling applications.
ART 6100
PRC to PRL conversion kit.
ART 949/PR
Optional device to make the fastening bracket of PRC series cable reels fixed instead of pivoting
Ordering Manufacting P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Cable type | Ø cable (mm) | Collettore maggiorato |
6386/PRL/IP65 | 1 X | 6 | 24 | H05V-F | 5.5 | * | |||
6384/PRL/IP65 | 1 X | 16 | 17 | H05V-F | 8 | * | |||
6383/PRL/IP65 | 2 X | 1 | 26 | 1 @230V | 7 @230V | H05VV-F | 6 | ||
6382/PRL/IP65 | 2 X | 1.5 | 24+2 | 1.1 @230V | 1.8 @230V | H05VV-F | 8 | ||
6380/PRL/IP65 | 2 X | 2.5 | 21+2 | 1.8 @230V | 2.5 @230V | H05VV-F | 9 | ||
6381/PRL/IP65 | 2 X | 2.5 | 21+2 | 1.8 @230V | 2.5 @230V | H05VV-F | 9 | * | |
6378/PRL/IP65 | 3 G | 1 | 24+2 | 1 @230V | 1.7 @230V | H05VV-F | 65 | ||
6377/PRL/IP65 | 3 G | 1.5 | 24+2 | 1.1 @230V | 1.8 @230V | H05VV-F | 7 | ||
6377/IP65 RNF | 3 G | 1.5 | 20+2 | 1.1 @230V | 1.8 @230V | H05VV-F | 95 | ||
6375/PRL/IP65 | 3 G | 2.5 | 15+2 | 2 @230V | 3 @230V | H07RN-F | 10 | ||
6376/PRL/IP65 | 3 G | 2.5 | 15+2 | 2 @230V | 3 @230V | H05VV-F | 10 | * | |
6375/IP65 RNF | 3 G | 2.5 | 12+2 | 2 @230V | 3 @230V | H05VV-F | 115 | ||
6376/IP65 RNF | 3 G | 2.5 | 12+2 | 2 @230V | 3 @230V | H07RN-F | 115 | * | |
6373/PRL/IP65 | 4 G | 1 | 24+2 | 0.8 @400V | 1.4 @400V | H07RN-F | 7 | ||
6372/PRL/IP65 | 4 G | 1.5 | 21+2 | 1.1 @400V | 1.8 @400V | H05VV-F | 85 | ||
6372/IP65 RNF | 4 G | 1.5 | 16+2 | 1.1 @400V | 1.8 @400V | H05VV-F | 105 | ||
6370/PRL/IP65 | 4 G | 2.5 | 15+2 | 2 @400V | 3 @400V | H07RN-F | 11 | ||
6370/IP65 RNF | 4 G | 2.5 | 10+2 | 2 @400V | 3 @400V | H05VV-F | 125 | ||
6525/PRL/IP65 | 4 G | 2.5 | 15+2 | 2 @400V | 3 @400V | H05VV-F | 11 | * | |
6525/IP65 RNF | 4 G | 2.5 | 10+2 | 2 @400V | 3 @400V | H07RN-F | 125 | * | |
6136/PRL/IP65 | 5 G | 1 | 16+2 | 0.8 @400V | 1.4 @400V | H05VV-F | 75 | ||
6140/PRL/IP65 | 5 G | 1.5 | 15+2 | 1.5 @400V | 2.2 @400V | H05VV-F | 95 | ||
6154/PRL/IP65 | 5 G | 2.5 | 10+2 | 2 @400V | 3 @400V | H05VV-F | 125 | ||
6154/IP65 RNF | 5 G | 2.5 | 8+2 | 2 @400V | 3 @400V | H07RN-F | 135 | ||
6138/PRL/IP65 | 7 X | 1 | 16+2 | H05VV-F | 85 | ||||
6142/PRL/IP65 | 7 X | 1.5 | 9+2 | H05VV-F | 105 | ||||
6139/PRL/IP65 | 8 X | 1 | 11+2 | H05VV-F | 10 | ||||
6143/PRL/IP65 | 8 X | 1.5 | 8+2 | H05VV-F | 115 |
ART 953
Roller cable-guide for cable reels PR series. Essential for ceiling applications.
ART 6100
PRC to PRL conversion kit.
ART 949/PR
Optional device to make the fastening bracket of PRC series cable reels fixed instead of pivoting
Ordering Manufacting P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Cable type | Ø cable (mm) | Collettore maggiorato |
6386/PRL/IP65 | 1 X | 6 | 24 | H05V-F | 5.5 | * | |||
6384/PRL/IP65 | 1 X | 16 | 17 | H05V-F | 8 | * | |||
6383/PRL/IP65 | 2 X | 1 | 26 | 1 @230V | 7 @230V | H05VV-F | 6 | ||
6382/PRL/IP65 | 2 X | 1.5 | 24+2 | 1.1 @230V | 1.8 @230V | H05VV-F | 8 | ||
6380/PRL/IP65 | 2 X | 2.5 | 21+2 | 1.8 @230V | 2.5 @230V | H05VV-F | 9 | ||
6381/PRL/IP65 | 2 X | 2.5 | 21+2 | 1.8 @230V | 2.5 @230V | H05VV-F | 9 | * | |
6378/PRL/IP65 | 3 G | 1 | 24+2 | 1 @230V | 1.7 @230V | H05VV-F | 65 | ||
6377/PRL/IP65 | 3 G | 1.5 | 24+2 | 1.1 @230V | 1.8 @230V | H05VV-F | 7 | ||
6377/IP65 RNF | 3 G | 1.5 | 20+2 | 1.1 @230V | 1.8 @230V | H05VV-F | 95 | ||
6375/PRL/IP65 | 3 G | 2.5 | 15+2 | 2 @230V | 3 @230V | H07RN-F | 10 | ||
6376/PRL/IP65 | 3 G | 2.5 | 15+2 | 2 @230V | 3 @230V | H05VV-F | 10 | * | |
6375/IP65 RNF | 3 G | 2.5 | 12+2 | 2 @230V | 3 @230V | H05VV-F | 115 | ||
6376/IP65 RNF | 3 G | 2.5 | 12+2 | 2 @230V | 3 @230V | H07RN-F | 115 | * | |
6373/PRL/IP65 | 4 G | 1 | 24+2 | 0.8 @400V | 1.4 @400V | H07RN-F | 7 | ||
6372/PRL/IP65 | 4 G | 1.5 | 21+2 | 1.1 @400V | 1.8 @400V | H05VV-F | 85 | ||
6372/IP65 RNF | 4 G | 1.5 | 16+2 | 1.1 @400V | 1.8 @400V | H05VV-F | 105 | ||
6370/PRL/IP65 | 4 G | 2.5 | 15+2 | 2 @400V | 3 @400V | H07RN-F | 11 | ||
6370/IP65 RNF | 4 G | 2.5 | 10+2 | 2 @400V | 3 @400V | H05VV-F | 125 | ||
6525/PRL/IP65 | 4 G | 2.5 | 15+2 | 2 @400V | 3 @400V | H05VV-F | 11 | * | |
6525/IP65 RNF | 4 G | 2.5 | 10+2 | 2 @400V | 3 @400V | H07RN-F | 125 | * | |
6136/PRL/IP65 | 5 G | 1 | 16+2 | 0.8 @400V | 1.4 @400V | H05VV-F | 75 | ||
6140/PRL/IP65 | 5 G | 1.5 | 15+2 | 1.5 @400V | 2.2 @400V | H05VV-F | 95 | ||
6154/PRL/IP65 | 5 G | 2.5 | 10+2 | 2 @400V | 3 @400V | H05VV-F | 125 | ||
6154/IP65 RNF | 5 G | 2.5 | 8+2 | 2 @400V | 3 @400V | H07RN-F | 135 | ||
6138/PRL/IP65 | 7 X | 1 | 16+2 | H05VV-F | 85 | ||||
6142/PRL/IP65 | 7 X | 1.5 | 9+2 | H05VV-F | 105 | ||||
6139/PRL/IP65 | 8 X | 1 | 11+2 | H05VV-F | 10 | ||||
6143/PRL/IP65 | 8 X | 1.5 | 8+2 | H05VV-F | 115 |
Art. 1401 – Swivelling bracket
Suitable only if the cable reel is manually used. To be installed with roller cable guide art. 1406.
Art. 1403 – Fixed bracket
For wall, floor or ceiling fastening. To be installed with roller cable guide art. 1406
Art. 1406 – Arm with roller cable guide
Complete with racket.
Ordering Manufacting P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Slipring Capacity (A) | Cable type | Ø cable (mm) |
1420 | 1 X | 16 | 22 | 50 | H05V-F | 8 | |||
1421 | 1 X | 25 | 20 | 100 | H05V-F | 10 | |||
1428 | 3 G | 2.5 | 22 | 3.5 @230V | 2 | 20 | H05VV-F | 10 | |
1428 RNF | 3 G | 2.5 | 20 | 3.5 @230V | 2 | 20 | H07RN-F | 11.5 | |
1429 | 3 G | 2.5 | 25 | 3.5 @230V | 2 | 20 | Igus CF900 | 85 | |
1430 | 3 G | 4 | 17 | 5 @230V | 3 | 20 | H05VV-F | 125 | |
1432 RNF | 4 G | 1.5 | 22 | 6 @400V | 4 | 50 | H07RN-F | 10.5 | |
1434 | 4 G | 2.5 | 20 | 10 @400V | 7 | 20 | H05VV-F | 11 | |
1434 RNF | 4 G | 2.5 | 17 | 10 @400V | 7 | 20 | H07RN-F | 12.5 | |
1435 | 4 G | 2.5 | 20 | 10 @400V | 7 | 20 | H05VV-F | 11 | |
1435 RNF | 4 G | 2.5 | 17 | 10 @400V | 7 | 50 | H07RN-F | 12.5 | |
1436 | 4 G | 4 | 14 | 15 @400V | 11 | 50 | H05VV-F | 14 | |
1436 RNF | 4 G | 4 | 12 | 15 @400V | 11 | 50 | H07RN-F | 15 | |
1438 RNF | 4 G | 6 | 10 | 22 @400V | 17 | 50 | H05VV-F | 17 | |
1440 | 5 G | 1.5 | 20 | 6 @400V | 4 | 50 | H07RN-F | 95 | |
1440 RNF | 5 G | 1.5 | 17 | 6 @400V | 4 | 20 | H05VV-F | 12 | |
1442 | 5 G | 2.5 | 17 | 10 @400V | 7 | 20 | H07RN-F | 125 | |
1442 RNF | 5 G | 2.5 | 14 | 10 @400V | 7 | 20 | H05VV-F | 13.5 | |
1443 | 5 G | 2.5 | 17 | 10 @400V | 7 | 20 | H07RN-F | 125 | |
1443 RNF | 5 G | 2.5 | 14 | 10 @400V | 7 | 50 | H05VV-F | 13.5 | |
1444 RNF | 5 G | 4 | 10 | 15 @400V | 11 | 50 | H07RN-F | 16.5 | |
1450 | 8 X | 1 | 20 | 50 | H05VV-F | 10 | |||
1452 | 8 X | 1.5 | 17 | 20 | H05VV-F | 115 | |||
1454 | 8 X | 2.5 | 14 | 20 | H05VV-F | 14 | |||
1460 | 12 X | 1 | 17 | 20 | H05VV-F | 13 | |||
1462 | 12 X | 1.5 | 14 | 20 | H05VV-F | 135 | |||
1464 | 12 X | 2.5 | 10 | 20 | H05VV-F | 16.5 |
Art. 1401 – Swivelling bracket
Suitable only if the cable reel is manually used. To be installed with roller cable guide art. 1406.
Art. 1403 – Fixed bracket
For wall, floor or ceiling fastening. To be installed with roller cable guide art. 1406
Art. 1406 – Arm with roller cable guide
Complete with racket.
Ordering Manufacting P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Slipring Capacity (A) | Cable type | Ø cable (mm) |
1420 | 1 X | 16 | 22 | 50 | H05V-F | 8 | |||
1421 | 1 X | 25 | 20 | 100 | H05V-F | 10 | |||
1428 | 3 G | 2.5 | 22 | 3.5 @230V | 2 | 20 | H05VV-F | 10 | |
1428 RNF | 3 G | 2.5 | 20 | 3.5 @230V | 2 | 20 | H07RN-F | 11.5 | |
1429 | 3 G | 2.5 | 25 | 3.5 @230V | 2 | 20 | Igus CF900 | 85 | |
1430 | 3 G | 4 | 17 | 5 @230V | 3 | 20 | H05VV-F | 125 | |
1432 RNF | 4 G | 1.5 | 22 | 6 @400V | 4 | 50 | H07RN-F | 10.5 | |
1434 | 4 G | 2.5 | 20 | 10 @400V | 7 | 20 | H05VV-F | 11 | |
1434 RNF | 4 G | 2.5 | 17 | 10 @400V | 7 | 20 | H07RN-F | 12.5 | |
1435 | 4 G | 2.5 | 20 | 10 @400V | 7 | 20 | H05VV-F | 11 | |
1435 RNF | 4 G | 2.5 | 17 | 10 @400V | 7 | 50 | H07RN-F | 12.5 | |
1436 | 4 G | 4 | 14 | 15 @400V | 11 | 50 | H05VV-F | 14 | |
1436 RNF | 4 G | 4 | 12 | 15 @400V | 11 | 50 | H07RN-F | 15 | |
1438 RNF | 4 G | 6 | 10 | 22 @400V | 17 | 50 | H05VV-F | 17 | |
1440 | 5 G | 1.5 | 20 | 6 @400V | 4 | 50 | H07RN-F | 95 | |
1440 RNF | 5 G | 1.5 | 17 | 6 @400V | 4 | 20 | H05VV-F | 12 | |
1442 | 5 G | 2.5 | 17 | 10 @400V | 7 | 20 | H07RN-F | 125 | |
1442 RNF | 5 G | 2.5 | 14 | 10 @400V | 7 | 20 | H05VV-F | 13.5 | |
1443 | 5 G | 2.5 | 17 | 10 @400V | 7 | 20 | H07RN-F | 125 | |
1443 RNF | 5 G | 2.5 | 14 | 10 @400V | 7 | 50 | H05VV-F | 13.5 | |
1444 RNF | 5 G | 4 | 10 | 15 @400V | 11 | 50 | H07RN-F | 16.5 | |
1450 | 8 X | 1 | 20 | 50 | H05VV-F | 10 | |||
1452 | 8 X | 1.5 | 17 | 20 | H05VV-F | 115 | |||
1454 | 8 X | 2.5 | 14 | 20 | H05VV-F | 14 | |||
1460 | 12 X | 1 | 17 | 20 | H05VV-F | 13 | |||
1462 | 12 X | 1.5 | 14 | 20 | H05VV-F | 135 | |||
1464 | 12 X | 2.5 | 10 | 20 | H05VV-F | 16.5 |
ART. 1701
Swivelling bracket, suitable only if the cable reel is manually used.
ART. 1702
Safety Return system. It slowdowns the winding of the cable, in case of uncontrolled release by user. Suggested for manual application.
ART. 1703
Fixed bracket, for wall, floor or ceiling fastening (the reel is standard delivered for a side fastening).
ART. 1704 – 1708
Swivelling arm for installation with middle travel feeding.
ART. 1706 – 1707
Swivelling arm with roller cable guide.
Ordering Manufacting P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Slipring Capacity (A) | Cable type | Ø cable (mm) |
1711 | 1 X | 16 | 30+2 | 60 | H05V-F | 8 | |||
1712 | 1 X | 25 | 30+2 | 100 | H05V-F | 10 | |||
170125/42 | 1 X | 25 | 100 | H05V-F | 10 | ||||
1717 | 3 G | 2.5 | 29+2 | 2 @230V | 3.5 @230V | 16 | H05VV-F | 10 | |
1717 RNF | 3 G | 2.5 | 29+2 | 2 @230V | 3.5 @230V | 16 | H07RN-F | 115 | |
1718 | 3 G | 2.5 | 39+2 | 2 @230V | 3.5 @230V | 16 | H05VV-F | 115 | |
1718 RNF | 3 G | 2.5 | 39+2 | 2 @230V | 3.5 @230V | 16 | H07RN-F | 115 | |
1721 -1 | 4 G | 2.5 | 20+2 | 7 @400V | 10 @400V | 32 | H05VV-F | 11 | |
1721 RNF | 4 G | 2.5 | 20+2 | 7 @400V | 10 @400V | 32 | H07RN-F | 125 | |
1722 | 4 G | 2.5 | 29+2 | 7 @400V | 10 @400V | 32 | H05VV-F | 11 | |
1722 RNF | 4 G | 2.5 | 29+2 | 7 @400V | 10 @400V | 32 | H07RN-F | 125 | |
1723 | 4 G | 2.5 | 39+2 | 6 @400V | 8.5 @400V | 32 | H05VV-F | 11 | |
1723 RNF | 4 G | 2.5 | 39+2 | 6 @400V | 8.5 @400V | 32 | H07RN-F | 125 | |
1724 | 4 G | 2.5 | 6 @400V | 8.5 @400V | 32 | H05VV-F | 11 | ||
1724 RNF | 4 G | 2.5 | 53+2 | 6 @400V | 8.5 @400V | 32 | H07RN-F | 125 | |
1726 | 4 G | 4 | 20+2 | 11 @400V | 15 @400V | 32 | H05VV-F | 14 | |
1726 RNF | 4 G | 4 | 15+2 | 11 @400V | 15 @400V | 32 | H07RN-F | 15 | |
1727 | 4 G | 4 | 20+2 | 11 @400V | 15 @400V | 60 | H05VV-F | 14 | |
1727 RNF | 4 G | 4 | 15+2 | 11 @400V | 15 @400V | 60 | H07RN-F | 15 | |
1728 | 4 G | 4 | 24+2 | 11 @400V | 15 @400V | 32 | H05V-F | 14 | |
1728 RNF | 4 G | 4 | 24+2 | 11 @400V | 15 @400V | 32 | H07RN-F | 15 | |
1729 | 4 G | 4 | 24+2 | 11 @400V | 15 @400V | 60 | H05VV-F | 14 | |
1729 RNF | 4 G | 4 | 24+2 | 11 @400V | 15 @400V | 60 | H07RN-F | 15 | |
1730 | 4 G | 4 | 29+2 | 11 @400V | 15 @400V | 32 | H05VV-F | 14 | |
1730 RNF | 4 G | 4 | 29+2 | 11 @400V | 15 @400V | 60 | H07RN-F | 14 | |
1731 | 4 G | 4 | 29+2 | 11 @400V | 15 @400V | 60 | H05VV-F | 14 | |
1731 RNF | 4 G | 4 | 29+2 | 11 @400V | 15 @400V | 60 | H07RN-F | 14 | |
1732 | 4 G | 4 | 43+2 | 10 @400V | 13.5 @400V | 32 | H05VV-F | 14 | |
1732 RNF | 4 G | 4 | 38+2 | 10 @400V | 13.5 @400V | 32 | H07RN-F | 15 | |
1733 | 4 G | 4 | 43+2 | 10 @400V | 13.5 @400V | 60 | H05VV-F | 14 | |
1733 RNF | 4 G | 4 | 38+2 | 10 @400V | 13.5 @400V | 60 | H07RN-F | 15 | |
1735 | 4 G | 6 | 15+2 | 17 @400V | 22 @400V | 60 | H05VV-F | 17 | |
1735 RNF | 4 G | 6 | 15+2 | 17 @400V | 22 @400V | 60 | H07RN-F | 17 | |
1736 | 4 G | 6 | 15+2 | 17 @400V | 22 @400V | 100 | H05VV-F | 17 | |
1736 RNF | 4 G | 6 | 15+2 | 17 @400V | 22 @400V | 100 | H07RN-F | 17 | |
1737 | 4 G | 6 | 24+2 | 17 @400V | 22 @400V | 60 | H05VV-F | 17 | |
1737 RNF | 4 G | 6 | 24+2 | 17 @400V | 22 @400V | 60 | H07RN-F | 17 | |
1738 | 4 G | 6 | 24+2 | 17 @400V | 22 @400V | 100 | H05VV-F | 17 | |
1738 RNF | 4 G | 6 | 24+2 | 17 @400V | 22 @400V | 100 | H07RN-F | 17 | |
1739 | 4 G | 6 | 38+2 | 17 @400V | 22 @400V | 60 | H05VV-F | 17 | |
1739 RNF | 4 G | 6 | 38+2 | 17 @400V | 22 @400V | 60 | H07RN-F | 17 | |
1740 | 4 G | 6 | 38+2 | 17 @400V | 22 @400V | 100 | H05VV-F | 17 | |
1740 RNF | 4 G | 6 | 38+2 | 25 @400V | 22 @400V | 100 | H07RN-F | 17 | |
1742 | 4 G | 10 | 14+2 | 25 @400V | 30 @400V | 60 | H05VV-F | 22 | |
1742 RNF | 4 G | 10 | 14+2 | 25 @400V | 30 @400V | 60 | H07RN-F | 22 | |
1743 | 4 G | 10 | 14+2 | 25 @400V | 30 @400V | 100 | H05VV-F | 22 | |
1743 RNF | 4 G | 10 | 14+2 | 25 @400V | 30 @400V | 100 | H07RN-F | 22 | |
1744 | 4 G | 10 | 23+2 | 25 @400V | 30 @400V | 60 | H05VV-F | 22 | |
1744 RNF | 4 G | 10 | 23+2 | 25 @400V | 30 @400V | 60 | H07RN-F | 22 | |
1745 | 4 G | 10 | 23+2 | 25 @400V | 30 @400V | 100 | H05VV-F | 22 | |
1745 RNF | 4 G | 10 | 23+2 | 25 @400V | 30 @400V | 100 | H07RN-F | 22 | |
1746 | 4 G | 10 | 38+2 | 25 @400V | 30 @400V | 60 | H05VV-F | 22 | |
1746 RNF | 4 G | 10 | 38+2 | 25 @400V | 30 @400V | 60 | H07RN-F | 22 | |
1747 | 4 G | 10 | 38+2 | 25 @400V | 30 @400V | 100 | H05VV-F | 22 | |
1747 RNF | 4 G | 10 | 38+2 | 25 @400V | 30 @400V | 100 | H07RN-F | 22 | |
1749 | 4 G | 16 | 14+2 | 35 @400V | 40 @400V | 100 | H05VV-F | 24 | |
1750 | 4 G | 16 | 28+2 | 35 @400V | 40 @400V | 100 | H05VV-F | 24 | |
170416/30T | 4 G | 28+2 | 35 @400V | 40 @400V | 100 | CF34.UL.160.05.D | 21 | ||
1752 | 5 G | 2.5 | 20+2 | 7 @400V | 9.5 @400V | 32 | H05VV-F | 12.5 | |
1752 RNF | 5 G | 2.5 | 20+2 | 7 @400V | 9.5 @400V | 32 | H07RN-F | 135 | |
1753 | 5 G | 2.5 | 24+2 | 7 @400V | 9.5 @400V | 32 | H05VV-F | 12.5 | |
1753 RNF | 5 G | 2.5 | 24+2 | 7 @400V | 9.5 @400V | 32 | H07RN-F | 135 | |
1754 | 5 G | 2.5 | 29+2 | 7 @400V | 9.5 @400V | 32 | H05VV-F | 12.5 | |
1754 RNF | 5 G | 2.5 | 29+2 | 7 @400V | 9.5 @400V | 32 | H07RN-F | 135 | |
1755 | 5 G | 2.5 | 53+2 | 6 @400V | 8.5 @400V | 32 | H05VV-F | 12.5 | |
1755 RNF | 5 G | 2.5 | 53+2 | 6 @400V | 8.5 @400V | 32 | H07RN-F | 135 | |
1757 | 5 G | 6 | 15+2 | 17 @400V | 22 @400V | 60 | H05VV-F | 17 | |
1757 RNF | 5 G | 6 | 14+2 | 17 @400V | 22 @400V | 60 | H07RN-F | 18.5 | |
1758 | 5 G | 6 | 15+2 | 17 @400V | 22 @400V | 100 | H05VV-F | 17 | |
1758 RNF | 5 G | 6 | 14+2 | 17 @400V | 22 @400V | 100 | H07RN-F | 18.5 | |
1759 | 5 G | 6 | 24+2 | 17 @400V | 22 @400V | 60 | H05VV-F | 17 | |
1759 RNF | 5 G | 6 | 24+2 | 17 @400V | 22 @400V | 60 | H07RN-F | 18.5 | |
1760 -1 | 5 G | 6 | 24+2 | 17 @400V | 22 @400V | 100 | H05VV-F | 17 | |
1760 RNF | 5 G | 6 | 24+2 | 17 @400V | 22 @400V | 100 | H05VV-F | 17 | |
1761 | 5 G | 6 | 38+2 | 17 @400V | 22 @400V | 60 | H05VV-F | 17 | |
1761 RNF | 5 G | 6 | 28+2 | 17 @400V | 22 @400V | 60 | H07RN-F | 18.5 | |
1762 | 5 G | 6 | 38+2 | 17 @400V | 22 @400V | 100 | H05VV-F | 17 | |
1762 RNF | 5 G | 6 | 28+2 | 17 @400V | 22 @400V | 100 | H07RN-F | 18.5 | |
170516/15 | 5 G | 16 | 13+2 | 35 @400V | 40 @400V | 100 | CF.30.100.05 | 24 | |
170516/30 | 5 G | 16 | 28+2 | 35 @400V | 40 @400V | 100 | CF.30.100.05 | 24 | |
170516/30T | 5 G | 16 | 28+2 | 35 @400V | 40 @400V | 100 | CF34.UL.160.05.D | 24 | |
1764 | 8 X | 1.5 | 20+2 | 35 @400V | 4.5 | 16 | H05VV-F | 115 | |
1765 | 8 X | 1.5 | 38+2 | 4.5 | 16 | H05VV-F | 115 | ||
1766 | 8 X | 2.5 | 15+2 | 7.5 | 16 | H05VV-F | 14 | ||
1767 | 8 X | 2.5 | 24+2 | 7.5 | 16 | H05VV-F | 14 | ||
1768 | 8 X | 2.5 | 38+2 | 7.5 | 16 | H05VV-F | 14 | ||
1769 | 8 X | 2.5 | 53+2 | 7.5 | 16 | H05VV-F | 14 | ||
1771 | 10 X | 1.5 | 15+2 | 4.5 | 16 | CF130 | 155 | ||
1772 | 10 X | 1.5 | 24+2 | 4.5 | 16 | CF130 | 155 | ||
1773 | 10 X | 1.5 | 53+2 | 4.5 | 16 | CF130 | 155 | ||
1775 | 12 X | 1.5 | 15+2 | 4.5 | 16 | CF130 | 135 | ||
1776 | 12 X | 1.5 | 24+2 | 4.5 | 16 | CF130 | 135 | ||
171215/40 | 12 X | 1.5 | 38+2 | 4.5 | 16 | CF130.15.12.UL | 13 | ||
1777 | 12 X | 1.5 | 53+2 | 4.5 | 16 | CF130 | 135 | ||
171225/17 | 12 X | 2.5 | 15+2 | 7.5 | 32 | CF130.25.12.UL | 175 | ||
171225/26 | 12 X | 2.5 | 24+2 | 7.5 | 32 | CF130.25.12.UL | 175 | ||
171225/40 | 12 X | 2.5 | 38+2 | 7.5 | 32 | CF130.25.12.UL | 175 | ||
1778 | 16 X | 1 | 30+2 | 3 | 16 | CF130 | 14 | ||
1779 | 16 X | 1.5 | 16+2 | 4.5 | 16 | CF130 | 175 | ||
1780 | 16 X | 1.5 | 24+2 | 4.5 | 16 | CF130 | 175 | ||
1781 | 16 X | 1.5 | 38+2 | 4.5 | 16 | CF130 | 175 | ||
1782 | 16 X | 2.5 | 16+2 | 7.5 | 16 | CF5 | 205 | ||
1783 | 16 X | 2.5 | 24+2 | 7.5 | 16 | CF5 | 205 | ||
1784 | 16 X | 2.5 | 38+2 | 7.5 | 16 | CF5 | 205 | ||
171815/17 | 18 X | 1.5 | 15+2 | 4.5 | 16 | CF130.15.18.UL | 175 | ||
171815/26 | 18 X | 1.5 | 24+2 | 4.5 | 16 | CF130.15.18.UL | 175 | ||
171815/40 | 18 X | 1.5 | 38+2 | 4.5 | 16 | CF130.15.18.UL | 175 | ||
171825/17 | 18 X | 2.5 | 15+2 | 7.5 | 32 | CF5.25.18 | 235 | ||
171825/26 | 18 X | 2.5 | 24+2 | 7.5 | 32 | CF5.25.18 | 235 | ||
171825/40 | 18 X | 2.5 | 38+2 | 7.5 | 32 | CF5.25.18 | 235 | ||
1787 | 24 X | 1.5 | 14+2 | 4.5 | 16 | CF130 | 20 | ||
1788 | 24 X | 1.5 | 23+2 | 4.5 | 16 | CF130 | 20 | ||
1789 | 24 X | 1.5 | 38+2 | 4.5 | 16 | CF130 | 20 | ||
172525/15T | 25 X | 2.5 | 13+2 | 7.5 | 32 | CF9.25.25 | 245 | ||
172525/25T | 25 X | 2.5 | 23+2 | 7.5 | 32 | CF9.25.25 | 245 |
ART. 1701
Swivelling bracket, suitable only if the cable reel is manually used.
ART. 1702
Safety Return system. It slowdowns the winding of the cable, in case of uncontrolled release by user. Suggested for manual application.
ART. 1703
Fixed bracket, for wall, floor or ceiling fastening (the reel is standard delivered for a side fastening).
ART. 1704 – 1708
Swivelling arm for installation with middle travel feeding.
ART. 1706 – 1707
Swivelling arm with roller cable guide.
Ordering Manufacting P/N:
Art. | Conductor number | Conductor section | Cable length (m) | KW cable wound | KW cable unwound | Max Current (A) | Slipring Capacity (A) | Cable type | Ø cable (mm) |
1711 | 1 X | 16 | 30+2 | 60 | H05V-F | 8 | |||
1712 | 1 X | 25 | 30+2 | 100 | H05V-F | 10 | |||
170125/42 | 1 X | 25 | 100 | H05V-F | 10 | ||||
1717 | 3 G | 2.5 | 29+2 | 2 @230V | 3.5 @230V | 16 | H05VV-F | 10 | |
1717 RNF | 3 G | 2.5 | 29+2 | 2 @230V | 3.5 @230V | 16 | H07RN-F | 115 | |
1718 | 3 G | 2.5 | 39+2 | 2 @230V | 3.5 @230V | 16 | H05VV-F | 115 | |
1718 RNF | 3 G | 2.5 | 39+2 | 2 @230V | 3.5 @230V | 16 | H07RN-F | 115 | |
1721 -1 | 4 G | 2.5 | 20+2 | 7 @400V | 10 @400V | 32 | H05VV-F | 11 | |
1721 RNF | 4 G | 2.5 | 20+2 | 7 @400V | 10 @400V | 32 | H07RN-F | 125 | |
1722 | 4 G | 2.5 | 29+2 | 7 @400V | 10 @400V | 32 | H05VV-F | 11 | |
1722 RNF | 4 G | 2.5 | 29+2 | 7 @400V | 10 @400V | 32 | H07RN-F | 125 | |
1723 | 4 G | 2.5 | 39+2 | 6 @400V | 8.5 @400V | 32 | H05VV-F | 11 | |
1723 RNF | 4 G | 2.5 | 39+2 | 6 @400V | 8.5 @400V | 32 | H07RN-F | 125 | |
1724 | 4 G | 2.5 | 6 @400V | 8.5 @400V | 32 | H05VV-F | 11 | ||
1724 RNF | 4 G | 2.5 | 53+2 | 6 @400V | 8.5 @400V | 32 | H07RN-F | 125 | |
1726 | 4 G | 4 | 20+2 | 11 @400V | 15 @400V | 32 | H05VV-F | 14 | |
1726 RNF | 4 G | 4 | 15+2 | 11 @400V | 15 @400V | 32 | H07RN-F | 15 | |
1727 | 4 G | 4 | 20+2 | 11 @400V | 15 @400V | 60 | H05VV-F | 14 | |
1727 RNF | 4 G | 4 | 15+2 | 11 @400V | 15 @400V | 60 | H07RN-F | 15 | |
1728 | 4 G | 4 | 24+2 | 11 @400V | 15 @400V | 32 | H05V-F | 14 | |
1728 RNF | 4 G | 4 | 24+2 | 11 @400V | 15 @400V | 32 | H07RN-F | 15 | |
1729 | 4 G | 4 | 24+2 | 11 @400V | 15 @400V | 60 | H05VV-F | 14 | |
1729 RNF | 4 G | 4 | 24+2 | 11 @400V | 15 @400V | 60 | H07RN-F | 15 | |
1730 | 4 G | 4 | 29+2 | 11 @400V | 15 @400V | 32 | H05VV-F | 14 | |
1730 RNF | 4 G | 4 | 29+2 | 11 @400V | 15 @400V | 60 | H07RN-F | 14 | |
1731 | 4 G | 4 | 29+2 | 11 @400V | 15 @400V | 60 | H05VV-F | 14 | |
1731 RNF | 4 G | 4 | 29+2 | 11 @400V | 15 @400V | 60 | H07RN-F | 14 | |
1732 | 4 G | 4 | 43+2 | 10 @400V | 13.5 @400V | 32 | H05VV-F | 14 | |
1732 RNF | 4 G | 4 | 38+2 | 10 @400V | 13.5 @400V | 32 | H07RN-F | 15 | |
1733 | 4 G | 4 | 43+2 | 10 @400V | 13.5 @400V | 60 | H05VV-F | 14 | |
1733 RNF | 4 G | 4 | 38+2 | 10 @400V | 13.5 @400V | 60 | H07RN-F | 15 | |
1735 | 4 G | 6 | 15+2 | 17 @400V | 22 @400V | 60 | H05VV-F | 17 | |
1735 RNF | 4 G | 6 | 15+2 | 17 @400V | 22 @400V | 60 | H07RN-F | 17 | |
1736 | 4 G | 6 | 15+2 | 17 @400V | 22 @400V | 100 | H05VV-F | 17 | |
1736 RNF | 4 G | 6 | 15+2 | 17 @400V | 22 @400V | 100 | H07RN-F | 17 | |
1737 | 4 G | 6 | 24+2 | 17 @400V | 22 @400V | 60 | H05VV-F | 17 | |
1737 RNF | 4 G | 6 | 24+2 | 17 @400V | 22 @400V | 60 | H07RN-F | 17 | |
1738 | 4 G | 6 | 24+2 | 17 @400V | 22 @400V | 100 | H05VV-F | 17 | |
1738 RNF | 4 G | 6 | 24+2 | 17 @400V | 22 @400V | 100 | H07RN-F | 17 | |
1739 | 4 G | 6 | 38+2 | 17 @400V | 22 @400V | 60 | H05VV-F | 17 | |
1739 RNF | 4 G | 6 | 38+2 | 17 @400V | 22 @400V | 60 | H07RN-F | 17 | |
1740 | 4 G | 6 | 38+2 | 17 @400V | 22 @400V | 100 | H05VV-F | 17 | |
1740 RNF | 4 G | 6 | 38+2 | 25 @400V | 22 @400V | 100 | H07RN-F | 17 | |
1742 | 4 G | 10 | 14+2 | 25 @400V | 30 @400V | 60 | H05VV-F | 22 | |
1742 RNF | 4 G | 10 | 14+2 | 25 @400V | 30 @400V | 60 | H07RN-F | 22 | |
1743 | 4 G | 10 | 14+2 | 25 @400V | 30 @400V | 100 | H05VV-F | 22 | |
1743 RNF | 4 G | 10 | 14+2 | 25 @400V | 30 @400V | 100 | H07RN-F | 22 | |
1744 | 4 G | 10 | 23+2 | 25 @400V | 30 @400V | 60 | H05VV-F | 22 | |
1744 RNF | 4 G | 10 | 23+2 | 25 @400V | 30 @400V | 60 | H07RN-F | 22 | |
1745 | 4 G | 10 | 23+2 | 25 @400V | 30 @400V | 100 | H05VV-F | 22 | |
1745 RNF | 4 G | 10 | 23+2 | 25 @400V | 30 @400V | 100 | H07RN-F | 22 | |
1746 | 4 G | 10 | 38+2 | 25 @400V | 30 @400V | 60 | H05VV-F | 22 | |
1746 RNF | 4 G | 10 | 38+2 | 25 @400V | 30 @400V | 60 | H07RN-F | 22 | |
1747 | 4 G | 10 | 38+2 | 25 @400V | 30 @400V | 100 | H05VV-F | 22 | |
1747 RNF | 4 G | 10 | 38+2 | 25 @400V | 30 @400V | 100 | H07RN-F | 22 | |
1749 | 4 G | 16 | 14+2 | 35 @400V | 40 @400V | 100 | H05VV-F | 24 | |
1750 | 4 G | 16 | 28+2 | 35 @400V | 40 @400V | 100 | H05VV-F | 24 | |
170416/30T | 4 G | 28+2 | 35 @400V | 40 @400V | 100 | CF34.UL.160.05.D | 21 | ||
1752 | 5 G | 2.5 | 20+2 | 7 @400V | 9.5 @400V | 32 | H05VV-F | 12.5 | |
1752 RNF | 5 G | 2.5 | 20+2 | 7 @400V | 9.5 @400V | 32 | H07RN-F | 135 | |
1753 | 5 G | 2.5 | 24+2 | 7 @400V | 9.5 @400V | 32 | H05VV-F | 12.5 | |
1753 RNF | 5 G | 2.5 | 24+2 | 7 @400V | 9.5 @400V | 32 | H07RN-F | 135 | |
1754 | 5 G | 2.5 | 29+2 | 7 @400V | 9.5 @400V | 32 | H05VV-F | 12.5 | |
1754 RNF | 5 G | 2.5 | 29+2 | 7 @400V | 9.5 @400V | 32 | H07RN-F | 135 | |
1755 | 5 G | 2.5 | 53+2 | 6 @400V | 8.5 @400V | 32 | H05VV-F | 12.5 | |
1755 RNF | 5 G | 2.5 | 53+2 | 6 @400V | 8.5 @400V | 32 | H07RN-F | 135 | |
1757 | 5 G | 6 | 15+2 | 17 @400V | 22 @400V | 60 | H05VV-F | 17 | |
1757 RNF | 5 G | 6 | 14+2 | 17 @400V | 22 @400V | 60 | H07RN-F | 18.5 | |
1758 | 5 G | 6 | 15+2 | 17 @400V | 22 @400V | 100 | H05VV-F | 17 | |
1758 RNF | 5 G | 6 | 14+2 | 17 @400V | 22 @400V | 100 | H07RN-F | 18.5 | |
1759 | 5 G | 6 | 24+2 | 17 @400V | 22 @400V | 60 | H05VV-F | 17 | |
1759 RNF | 5 G | 6 | 24+2 | 17 @400V | 22 @400V | 60 | H07RN-F | 18.5 | |
1760 -1 | 5 G | 6 | 24+2 | 17 @400V | 22 @400V | 100 | H05VV-F | 17 | |
1760 RNF | 5 G | 6 | 24+2 | 17 @400V | 22 @400V | 100 | H05VV-F | 17 | |
1761 | 5 G | 6 | 38+2 | 17 @400V | 22 @400V | 60 | H05VV-F | 17 | |
1761 RNF | 5 G | 6 | 28+2 | 17 @400V | 22 @400V | 60 | H07RN-F | 18.5 | |
1762 | 5 G | 6 | 38+2 | 17 @400V | 22 @400V | 100 | H05VV-F | 17 | |
1762 RNF | 5 G | 6 | 28+2 | 17 @400V | 22 @400V | 100 | H07RN-F | 18.5 | |
170516/15 | 5 G | 16 | 13+2 | 35 @400V | 40 @400V | 100 | CF.30.100.05 | 24 | |
170516/30 | 5 G | 16 | 28+2 | 35 @400V | 40 @400V | 100 | CF.30.100.05 | 24 | |
170516/30T | 5 G | 16 | 28+2 | 35 @400V | 40 @400V | 100 | CF34.UL.160.05.D | 24 | |
1764 | 8 X | 1.5 | 20+2 | 35 @400V | 4.5 | 16 | H05VV-F | 115 | |
1765 | 8 X | 1.5 | 38+2 | 4.5 | 16 | H05VV-F | 115 | ||
1766 | 8 X | 2.5 | 15+2 | 7.5 | 16 | H05VV-F | 14 | ||
1767 | 8 X | 2.5 | 24+2 | 7.5 | 16 | H05VV-F | 14 | ||
1768 | 8 X | 2.5 | 38+2 | 7.5 | 16 | H05VV-F | 14 | ||
1769 | 8 X | 2.5 | 53+2 | 7.5 | 16 | H05VV-F | 14 | ||
1771 | 10 X | 1.5 | 15+2 | 4.5 | 16 | CF130 | 155 | ||
1772 | 10 X | 1.5 | 24+2 | 4.5 | 16 | CF130 | 155 | ||
1773 | 10 X | 1.5 | 53+2 | 4.5 | 16 | CF130 | 155 | ||
1775 | 12 X | 1.5 | 15+2 | 4.5 | 16 | CF130 | 135 | ||
1776 | 12 X | 1.5 | 24+2 | 4.5 | 16 | CF130 | 135 | ||
171215/40 | 12 X | 1.5 | 38+2 | 4.5 | 16 | CF130.15.12.UL | 13 | ||
1777 | 12 X | 1.5 | 53+2 | 4.5 | 16 | CF130 | 135 | ||
171225/17 | 12 X | 2.5 | 15+2 | 7.5 | 32 | CF130.25.12.UL | 175 | ||
171225/26 | 12 X | 2.5 | 24+2 | 7.5 | 32 | CF130.25.12.UL | 175 | ||
171225/40 | 12 X | 2.5 | 38+2 | 7.5 | 32 | CF130.25.12.UL | 175 | ||
1778 | 16 X | 1 | 30+2 | 3 | 16 | CF130 | 14 | ||
1779 | 16 X | 1.5 | 16+2 | 4.5 | 16 | CF130 | 175 | ||
1780 | 16 X | 1.5 | 24+2 | 4.5 | 16 | CF130 | 175 | ||
1781 | 16 X | 1.5 | 38+2 | 4.5 | 16 | CF130 | 175 | ||
1782 | 16 X | 2.5 | 16+2 | 7.5 | 16 | CF5 | 205 | ||
1783 | 16 X | 2.5 | 24+2 | 7.5 | 16 | CF5 | 205 | ||
1784 | 16 X | 2.5 | 38+2 | 7.5 | 16 | CF5 | 205 | ||
171815/17 | 18 X | 1.5 | 15+2 | 4.5 | 16 | CF130.15.18.UL | 175 | ||
171815/26 | 18 X | 1.5 | 24+2 | 4.5 | 16 | CF130.15.18.UL | 175 | ||
171815/40 | 18 X | 1.5 | 38+2 | 4.5 | 16 | CF130.15.18.UL | 175 | ||
171825/17 | 18 X | 2.5 | 15+2 | 7.5 | 32 | CF5.25.18 | 235 | ||
171825/26 | 18 X | 2.5 | 24+2 | 7.5 | 32 | CF5.25.18 | 235 | ||
171825/40 | 18 X | 2.5 | 38+2 | 7.5 | 32 | CF5.25.18 | 235 | ||
1787 | 24 X | 1.5 | 14+2 | 4.5 | 16 | CF130 | 20 | ||
1788 | 24 X | 1.5 | 23+2 | 4.5 | 16 | CF130 | 20 | ||
1789 | 24 X | 1.5 | 38+2 | 4.5 | 16 | CF130 | 20 | ||
172525/15T | 25 X | 2.5 | 13+2 | 7.5 | 32 | CF9.25.25 | 245 | ||
172525/25T | 25 X | 2.5 | 23+2 | 7.5 | 32 | CF9.25.25 | 245 |
Serie 1800 cable reel accessories
Ordering Manufacting P/N:
Art. | Conductor number | Conductor section | Cable length (m) | Slipring Capacity (A) | Cable type | Ø cable (mm) |
180406/50RA | 4 G | 6 | 50 | 60 | H07RN-F | 17 |
180406/50RB | 4 G | 6 | 50 | 100 | H07RN-F | 17 |
180410/50R | 4 G | 10 | 50 | 100 | H07RN-F | 22 |
180410/50T | 4 G | 10 | 50 | 100 | CF34.UL.100.04.D | 17 |
180416/40 | 4 G | 16 | 40 | 100 | CF30.160.04 | 21 |
180416/40T | 4 G | 16 | 40 | 100 | CF34.UL.160.04.D | 21 |
180425/40T | 4 G | 25 | 40 | 100 | CF34.UL.250.04.D | 25 |
180506/50RA | 5 G | 6 | 50 | 60 | H07RN-F | 185 |
180506/50RB | 5 G | 6 | 50 | 100 | H07RN-F | 185 |
180510/50 | 5 G | 10 | 50 | 100 | CF.30.100.05 | 20 |
180510/50T | 5 G | 10 | 50 | 100 | CF34.UL.100.05.D | 20 |
180516/40 | 5 G | 16 | 40 | 100 | CF30.160.05 | 24 |
180516/40T | 5 G | 16 | 40 | 100 | CF34.UL.160.05.D | 19 |
181225/50 | 12 X | 2.5 | 50 | 32 | CF130.25.12.UL | 175 |
181225/50P | 12 X | 2.5 | 50 | 32 | CF77.UL.25.12.D | 175 |
181825/50 | 18 X | 2.5 | 50 | 32 | CF5.25.18 | 235 |
181825/50T | 18 X | 2.5 | 50 | 32 | CF9.25.18 | 23 |
182515/50 | 25 X | 1.5 | 50 | 16 | CF130.15.25.UL | 195 |
182515/50P | 25 X | 1.5 | 50 | 16 | CF77.UL.15.25.D | 195 |
182525/40T | 25 X | 2.5 | 40 | 32 | CF9.25.25 | 245 |
Serie 1800 cable reel accessories
Ordering Manufacting P/N:
Art. | Conductor number | Conductor section | Cable length (m) | Slipring Capacity (A) | Cable type | Ø cable (mm) |
180406/50RA | 4 G | 6 | 50 | 60 | H07RN-F | 17 |
180406/50RB | 4 G | 6 | 50 | 100 | H07RN-F | 17 |
180410/50R | 4 G | 10 | 50 | 100 | H07RN-F | 22 |
180410/50T | 4 G | 10 | 50 | 100 | CF34.UL.100.04.D | 17 |
180416/40 | 4 G | 16 | 40 | 100 | CF30.160.04 | 21 |
180416/40T | 4 G | 16 | 40 | 100 | CF34.UL.160.04.D | 21 |
180425/40T | 4 G | 25 | 40 | 100 | CF34.UL.250.04.D | 25 |
180506/50RA | 5 G | 6 | 50 | 60 | H07RN-F | 185 |
180506/50RB | 5 G | 6 | 50 | 100 | H07RN-F | 185 |
180510/50 | 5 G | 10 | 50 | 100 | CF.30.100.05 | 20 |
180510/50T | 5 G | 10 | 50 | 100 | CF34.UL.100.05.D | 20 |
180516/40 | 5 G | 16 | 40 | 100 | CF30.160.05 | 24 |
180516/40T | 5 G | 16 | 40 | 100 | CF34.UL.160.05.D | 19 |
181225/50 | 12 X | 2.5 | 50 | 32 | CF130.25.12.UL | 175 |
181225/50P | 12 X | 2.5 | 50 | 32 | CF77.UL.25.12.D | 175 |
181825/50 | 18 X | 2.5 | 50 | 32 | CF5.25.18 | 235 |
181825/50T | 18 X | 2.5 | 50 | 32 | CF9.25.18 | 23 |
182515/50 | 25 X | 1.5 | 50 | 16 | CF130.15.25.UL | 195 |
182515/50P | 25 X | 1.5 | 50 | 16 | CF77.UL.15.25.D | 195 |
182525/40T | 25 X | 2.5 | 40 | 32 | CF9.25.25 | 245 |
1 Tampines North Drive 1 #04-27
T-Space Singapore 528559
T: +65 6686 0878
F: +65 6686 0085
E: ccsl@ccsl.com.sg